Add to Cart
large diameter hot water meter & Woltmann
Working condition(s)
Water temperature 0.1~90℃, Working pressure ≤1MPa.(1.6Mpa available)
Accuracy
Low region max. allowable error: From Q1 inclusive up to but excluding Q2 is ± 5%.
High region max. allowable error: From Q2 inclusive up to and including Q 4 is ± 2%.
|    Product model  |      Diameter  |      Flow rate m³/h  |      Indication  |   |||||||
|    Initial flow rate  |      Overload flow rate (Q4)  |      Normal flow rate (Q3)  |      Transitional flow rate (Q2)  |      Min. flow rate (Q1)  |      Min Reading (Min)  |      Max. Reading (Max)  |   ||||
|    Horizontal Woltman water meter  |      W P H  |      Cold water: R80 Q2/Q1=6.3 GB/T 778.1-2007 Heat water: R50 Q2/Q1=6.3 GB/T 778.1-2007 0.0005  |      Dry type: 999999.999  |   |||||||
|    40  |      -  |      50/31  |      40/25  |      3.15  |      0.5  |      0.001  |   ||||
|    50  |      -  |      50/31  |      40/25  |      3.15  |      0.5  |   |||||
|    65  |      -  |      80/50  |      63/40  |      5.0  |      0.79  |   |||||
|    80  |      -  |      125/78  |      100/63  |      7.90  |      1.25  |   |||||
|    100  |      -  |      200/125  |      160/100  |      12.6  |      2.0  |   |||||
|    125  |      -  |      312/200  |      250/160  |      19.7  |      3.12  |   |||||
|    150  |      -  |      500/312  |      400/250  |      31.5  |      5.0  |      0.01  |   ||||
|    200  |      -  |      780/500  |      630/400  |      50.4  |      8.0  |   |||||
Pressure Loss Curve
    
 